Gas Control Valve Cv Sizing

Calculate the flow coefficient (Cv) for gas control valves per ISA/IEC 60534.

Gas Control Valve Sizing Calculator Guide (PDF)

This calculator is used to size gas control valves. The calculator determines the valve flow coefficient (Cv) required for a specified gas flow rate and pressure drop. The calculator can handle non-choked and choked flow. The calculation method is based on the International Electrotechnical Commission procedure described in the Emerson Control Valve Handbook.

The calculator can handle non-choked and choked flow.

  1. Enter the mass flow rate of gas the valve must pass
  2. Enter the pressures upstream and downstream of the valve
  3. Enter the fluid physical properties
  4. Enter the valve pressure drop ratio factor
    • This can be obtained from valve manufacturer's literature
    • Typical values for globe valves range from 0.50 to 0.92
  5. Enter the piping geometry factor
    • If no fittings are connected to the valve this factor is 1
    • If fittings such as reducers are fitted to the valve the geometry factor can be calculated using the procedure described in the Gas Control Valve Sizing Calculator Guide
  6. Click the "Calculate" button
  7. The calculator will determine the valve Cv
  8. The calculator will also determine if the flow is critical or not through the valve
Log in to save and load calculations
INPUTS
Gas mass flow rate w
Upstream pressure P1
Downstream pressure P2
Fluid density ρ
Gas ratio of specific heat capacities k
Pressure drop ratio factor XT
Piping geometry factor FP
OUTPUTS
Ratio of specific heats factor Fk 1.0
Pressure drop across valve ΔP 5.0
Pressure drop ratio X 0.5
Critical flow?   NO
Effective pressure drop ratio Xeff 0.5
Expansion factor Y 0.792
Valve flow coefficient Cv 5.7837
Download Calculation Report

Get this calculation as a professional PDF with full methodology, equations and substituted values — ready for your project file.